Unable to create a "Send to Connection"- verification failed -url is a not a valid routing destination
ISSUE :
Unable to successfully create a send to connection.When creating the Send to connection from Sharepoint 2010 Central Administration and click on Test URL for the Destination URL , we get the following error
"verification failed -url is a not a valid routing destination"
we see the following entry in the ULS logs
Url validation failed for http://gmallya.test.com/sites/testrecordcenter/_vti_bin/OfficialFile.asmx during Record and document center connection configuration with exception The request failed with HTTP status 401: Unauthorized.: at System.Web.Services.Protocols.SoapHttpClientProtocol.ReadResponse(SoapClientMessage message, WebResponse response, Stream responseStream, Boolean asyncCall) at System.Web.Services.Protocols.SoapHttpClientProtocol.Invoke(String methodName, Object[] parameters) at Microsoft.SharePoint.OfficialFileSoap.GetServerInfo() at Microsoft.SharePoint.ApplicationPages.OfficialFileAdminPage.<>c__DisplayClass2.<IsValidUriToRouter>b__0() at Microsoft.SharePoint.SPSecurity.<>c__DisplayClass4.<RunWithElevatedPrivileges>b__2() at Microsoft.SharePoint.Utilities.SecurityContext.RunAsProcess(CodeToRunElevated secureCode) at Microsoft.SharePoint.SPSecurity.RunWithElevatedPrivileges(WaitCallback secureCode, Object param) at Microsoft.SharePoint.SPSecurity.RunWithElevatedPrivileges(CodeToRunElevated secureCode) at Microsoft.SharePoint.ApplicationPages.OfficialFileAdminPage.IsValidUriToRouter(Uri uriToValidate)
CAUSE
Loop Back Check registry value is EnabledRESOLUTION
Follow the article to disable the loop back check-
Click Start, click Run, type regedit, and then click OK.
1.In Registry Editor, locate and then click the following registry key: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Lsa
2.Right-click Lsa, point to New, and then click DWORD Value.
3.Type DisableLoopbackCheck, and then press ENTER.
4.Right-click DisableLoopbackCheck, and then click Modify.
5.In the Value data box, type 1, and then click OK.
6.Quit Registry Editor, and then restart your computer.
Now create a "Send To" connection successfully..!!